12V Underfloor Heating Thermostat 2 outputs

79.56

12V Underfloor Heating Thermostat 2 outputs incl. mounting frame. Can be used used for our 12V underfloor heating system but with 2 zones could also be used for other purposes. It is a two-sensor thermostat designed to control temperature in heating and cooling systems. The device consists of two regulators enclosed in a common housing. Control inputs and outputs can operate in heating or cooling mode. Thanks to the use of mathematical functions, the measurement from one or the other sensor (or two at the same time) can be calculated in the form of a difference or an average. The controller has a digital temperature display and measured value adjustment function. The accuracy of the temperature control (hysteresis) is adjustable between 0.1 – 20.0C. The controller has a maximum switching capacity of 16A per zone. The operating mode “heating” or “cooling” can be set via the menu.

Temperature reading on the controller
The  regulator has a digital temperature readout and the ability to calibrate the readings. The value from both sensors is displayed alternately every three seconds. The user can set the regulator to display a single reading. The built-in siren has been designed in such a way that it provides acoustic information about the activation of outputs and alarm states.
Two-channel controllers maintain the object temperature with hysteresis set in the range of 0.1 to 20.0°C. Uses can include Independent control system for two heaters and a control system for two heaters with two temperature settings. As the device uses 2 16A relays as opposed to one 20A relay it can also handle a higher load this allowing more heating power if required with also the option of multiple zones.

Basic information:
2 REGULATORS in one housing
2 measurement inputs
2 control output
Connect T1 and T2 alternately
Mathematical functions (average, differential measurement)
Possibility of linking REGULATORS among themselves (e.g. OUT1 = on, when OUT2 = off)
Digital input for manual operation or signal.
Built-in sound indicator (buzzer)

Hole dimensions: 71 x 29mm

Degree and class of protection:IP65/II

Power supply:  12VAC/DC

Power consumption: max. 3 VA

Working conditions: -5 … 60°C; 0 … 85% RH (non-condensing)

Storage conditions: -40 … 85°C; 0 … 85% RH (non-condensing)

Made in EU

Contents  1 controller and 2 temperature sensors

12v Timer
This item: 12V Underfloor Heating Thermostat 2 outputs
79.56
79.56
12V Underfloor heating
136.23
SKU: M10THERMO2 Categories: ,

Description

12V Underfloor Heating Thermostat 2 outputs incl. mounting frame. Can be used used for our 12V underfloor heating system but with 2 zones could also be used for other purposes. It is a two-sensor thermostat designed to control temperature in heating and cooling systems. The device consists of two regulators enclosed in a common housing. Control inputs and outputs can operate in heating or cooling mode. Thanks to the use of mathematical functions, the measurement from one or the other sensor (or two at the same time) can be calculated in the form of a difference or an average. The controller has a digital temperature display and measured value adjustment function. The accuracy of the temperature control (hysteresis) is adjustable between 0.1 – 20.0C. The controller has a maximum switching capacity of 16A per zone. The operating mode “heating” or “cooling” can be set via the menu.

Temperature reading on the controller
The  regulator has a digital temperature readout and the ability to calibrate the readings. The value from both sensors is displayed alternately every three seconds. The user can set the regulator to display a single reading. The built-in siren has been designed in such a way that it provides acoustic information about the activation of outputs and alarm states.
Two-channel controllers maintain the object temperature with hysteresis set in the range of 0.1 to 20.0°C. Uses can include Independent control system for two heaters and a control system for two heaters with two temperature settings. As the device uses 2 16A relays as opposed to one 20A relay it can also handle a higher load this allowing more heating power if required with also the option of multiple zones.

Basic information:
2 REGULATORS in one housing
2 measurement inputs
2 control output
Connect T1 and T2 alternately
Mathematical functions (average, differential measurement)
Possibility of linking REGULATORS among themselves (e.g. OUT1 = on, when OUT2 = off)
Digital input for manual operation or signal. CEMENT
Built-in sound indicator (buzzer)

Technical data

Entry: 2 NTC 5kOhm temperature sensors at 25°C digital input (standard open or closed)

Measurement range: -50 … + 150°C

Measurement accuracy:+/- 0.5°C

Sampling period:330 ms

Display resolution:0.1°C over the entire range

Setting resolution:0.1°C over the entire range

Display:LED, 4 digits, 11mm high, with graphic icons

Adjustment method:ON-OFF with hysteresis

Adjustment accuracy:adjustable in the range 0.1 … 20.0°C

Control outputs:

1 relay 16A, 3.6kW, durability 100,000 cycles
1 relay 16A, 3.6kW, durability 100,000 cycles

Additional features:

– mathematical functions (measurement of difference, average)

– selection of the temperature channel to be read

– sound signaling of alarm states

– possibility of linking both measurement outputs

Installation:

Hole dimensions: 71 x 29mm

Degree and class of protection:IP65/II

Power supply:  12VAC/DC

Power consumption: max. 3 VA

Working conditions: -5 … 60°C; 0 … 85% RH (non-condensing)

Storage conditions: -40 … 85°C; 0 … 85% RH (non-condensing)

Made in EU

Contents  1 controller and 2 temperature sensors

Additional information

Weight 1 kg
Dimensions 50 × 30 × 30 cm

Reviews

There are no reviews yet.

Be the first to review “12V Underfloor Heating Thermostat 2 outputs”